ISO 9001 · 14001 · 45001 — Certified quality systemkaren.yeh@yeh-tek.comWhatsApp
Get a quote
Support · Simulation & FEA

Simulate first.
Tool once.

Ansys magnetic-circuit analysis and Moldflow injection simulation — run on your drawing before a single die is cut.

Pull-Force Simulation

We perform accurate attraction force simulation to predict the magnetic pull force under different air gaps and assembly conditions. It helps verify whether the suction force meets your design targets in advance, avoiding insufficient or excessive magnetic force after sample production.

Pull force vs. air gap — simulation result
Pull force vs. air gap — simulation result

Magnetic Force Simulation

Comprehensive magnetic force simulation covers magnetic attraction, repulsion, lateral force and torque. We analyze magnetic interaction between magnets and conductive parts, optimize structure to reduce unwanted force deviation and ensure stable operation of your magnetic assemblies.

Magnetic force & torque analysis
Magnetic force & torque analysis

3D Field Distribution

3D magnetic field simulation visualizes the spatial distribution of magnetic flux density, flux lines and loss. We detect magnetic leakage, uneven flux and hot spots in the early design stage, refine the magnetic circuit structure and improve the utilization rate of magnetic materials.

3D flux density distribution
3D flux density distribution

Thermal & Coupled Analysis

Temperature rise and coupled magneto-thermal analysis for assemblies operating under continuous load — so the grade, coating and geometry you choose still perform after hours on the line, not just on the bench.

Coupled FEA model library
Coupled FEA model library

Example — pull force vs. displacement (304 steel plate)

CaseFx (kgf)Fy (kgf)Fz (kgf)F resultant (kgf)
Initial position0.00-0.46-0.070.47
Move +Z 10 mm0.000.02-0.030.03
Move +X 10 mm-0.09-0.20-0.030.22

F is the resultant force. Both +X and +Z displacement cases are calculated: moving in +Z gives theoretical Fx = 0, which cannot satisfy Fx / Fz ≥ 0.4 — after a 10 mm move in +X, Fx / Fz = 0.45. Steel plate is 304 stainless (430 pull force ≈ 12% lower, results omitted). Delivered with every simulation report.

Example — Halbach array vs. conventional stack

ComparisonConventionalHalbach
Magnet volumeSameSame
Pull force at same gapWeakStrong
Single-sided shieldingWeakStrong
Number of magnet blocksFewerMore
Need this applied to your part?Send the drawing — our engineers will run the numbers for Simulation & FEA and reply within 12 working hours.
Contact our engineer →