Simulate first.
Tool once.
Ansys magnetic-circuit analysis and Moldflow injection simulation — run on your drawing before a single die is cut.
Pull-Force Simulation
We perform accurate attraction force simulation to predict the magnetic pull force under different air gaps and assembly conditions. It helps verify whether the suction force meets your design targets in advance, avoiding insufficient or excessive magnetic force after sample production.

Magnetic Force Simulation
Comprehensive magnetic force simulation covers magnetic attraction, repulsion, lateral force and torque. We analyze magnetic interaction between magnets and conductive parts, optimize structure to reduce unwanted force deviation and ensure stable operation of your magnetic assemblies.

3D Field Distribution
3D magnetic field simulation visualizes the spatial distribution of magnetic flux density, flux lines and loss. We detect magnetic leakage, uneven flux and hot spots in the early design stage, refine the magnetic circuit structure and improve the utilization rate of magnetic materials.

Thermal & Coupled Analysis
Temperature rise and coupled magneto-thermal analysis for assemblies operating under continuous load — so the grade, coating and geometry you choose still perform after hours on the line, not just on the bench.

Example — pull force vs. displacement (304 steel plate)
| Case | Fx (kgf) | Fy (kgf) | Fz (kgf) | F resultant (kgf) |
|---|---|---|---|---|
| Initial position | 0.00 | -0.46 | -0.07 | 0.47 |
| Move +Z 10 mm | 0.00 | 0.02 | -0.03 | 0.03 |
| Move +X 10 mm | -0.09 | -0.20 | -0.03 | 0.22 |
F is the resultant force. Both +X and +Z displacement cases are calculated: moving in +Z gives theoretical Fx = 0, which cannot satisfy Fx / Fz ≥ 0.4 — after a 10 mm move in +X, Fx / Fz = 0.45. Steel plate is 304 stainless (430 pull force ≈ 12% lower, results omitted). Delivered with every simulation report.
Example — Halbach array vs. conventional stack
| Comparison | Conventional | Halbach |
|---|---|---|
| Magnet volume | Same | Same |
| Pull force at same gap | Weak | Strong |
| Single-sided shielding | Weak | Strong |
| Number of magnet blocks | Fewer | More |